Welcome to GCSE Edexcel Science revision.

00:00:04.125 --> 00:00:07.819
Unit S P 13: Electromagnetic induction.

00:00:10.500 --> 00:00:18.424
A changing magnetic field through a coil or relative motion that cuts magnetic field lines can induce a potential difference.

00:00:18.574 --> 00:00:20.985
This is electromagnetic induction.

00:00:23.667 --> 00:00:27.945
Moving a magnet into or out of a coil changes the field through the coil.

00:00:28.095 --> 00:00:33.182
A sensitive voltmeter connected across the coil can detect an induced voltage.

00:00:33.332 --> 00:00:38.013
The voltmeter measures potential difference, with polarity set by connections.

00:00:42.667 --> 00:00:48.042
If the coil is part of a closed conducting circuit, the induced voltage drives a current.

00:00:48.192 --> 00:00:52.343
An open circuit can have induced voltage but no continuing current.

00:00:55.000 --> 00:01:03.543
A stationary magnet held within a stationary coil does not produce a continuing induced voltage because the field through the coil is not changing.

00:01:06.200 --> 00:01:13.494
Faster magnet movement, a stronger magnet or more coil turns can increase induced voltage when the other factors are fixed.

00:01:16.167 --> 00:01:21.617
Reverse the motion or reverse the magnet's poles to reverse the induced voltage direction.

00:01:21.767 --> 00:01:24.922
Reversing both can keep the direction unchanged.

00:01:27.600 --> 00:01:32.325
The field associated with the induced current opposes the original change.

00:01:32.475 --> 00:01:41.999
An approaching north pole induces a facing north pole that resists approach; a withdrawing north pole induces a facing south pole that resists separation.

00:01:42.149 --> 00:01:45.931
Both induced interactions resist the change that created them.

00:01:50.600 --> 00:01:57.095
This opposition means mechanical work is needed to maintain motion when electrical energy is transferred.

00:01:57.245 --> 00:01:59.698
Induction does not produce free energy.

00:02:02.367 --> 00:02:06.806
Connect a coil to a sensitive centre-zero voltmeter or data logger.

00:02:06.956 --> 00:02:12.587
Move a bar magnet in and out and record size and sign of voltage; compare with holding it still.

00:02:15.267 --> 00:02:20.087
Change one factor at a time: magnet speed, magnet strength or number of turns.

00:02:20.237 --> 00:02:25.357
Keep coil size, movement path, starting positions and other variables consistent.

00:02:28.033 --> 00:02:34.293
For fair comparisons, use repeatable movement and compare the same part of the movement or peak voltage.

00:02:34.443 --> 00:02:38.026
Repeat trials because hand movement gives varying speed.

00:02:40.700 --> 00:02:45.637
Investigate direction by reversing magnet motion or poles individually.

00:02:45.787 --> 00:02:49.923
Label which end of the coil is connected to the positive voltmeter terminal.

00:02:52.600 --> 00:02:59.318
A voltage pulse depends on the rate of field change, not simply how much magnetic material is sitting inside a coil.

00:03:02.000 --> 00:03:07.003
A transformer has a primary coil and a secondary coil linked by a magnetic core.

00:03:07.153 --> 00:03:10.828
The coils are electrically separate in the usual ideal model.

00:03:10.978 --> 00:03:14.505
A changing magnetic field transfers energy between them.

00:03:14.655 --> 00:03:18.773
Coils are magnetically coupled, not joined by an electrical wire.

00:03:23.433 --> 00:03:28.627
An alternating current in the primary creates a changing magnetic field in the core.

00:03:28.777 --> 00:03:33.309
The changing field through the secondary induces an alternating voltage.

00:03:35.967 --> 00:03:39.410
A secondary current flows if a load completes its circuit.

00:03:39.560 --> 00:03:45.415
An unloaded secondary can have voltage with little output power because there is little load current.

00:03:48.067 --> 00:03:54.647
A steady D C input does not provide the continuously changing field needed for normal transformer operation.

00:03:54.797 --> 00:04:00.599
Switching D C on or off can produce brief changes, not a sustained transformed output.

00:04:03.267 --> 00:04:08.621
A step-up transformer increases A C voltage; a step-down transformer decreases it.

00:04:08.771 --> 00:04:14.231
More secondary than primary turns gives step-up behaviour; fewer gives step-down behaviour.

00:04:16.900 --> 00:04:19.947
The core helps the magnetic field link both coils.

00:04:20.097 --> 00:04:28.265
Real transformers transfer some energy to the surroundings, including by heating, so their useful output power is less than their input power.

00:04:30.933 --> 00:04:36.256
For a transformer assumed one hundred percent efficient, input power equals output power.

00:04:36.406 --> 00:04:45.364
Use primary voltage times primary current equals secondary voltage times secondary current, with voltages in volts and currents in amperes.

00:04:48.033 --> 00:04:53.599
A primary of 230 volts and 2 amperes supplies 460 watts.

00:04:53.749 --> 00:05:01.193
If the ideal secondary is 23 volts, its current is 460 divided by 23 equals 20 amperes.

00:05:01.343 --> 00:05:05.083
Lower output voltage permits greater current at the same power.

00:05:09.733 --> 00:05:15.897
Increasing voltage reduces current for the same transferred power; reducing voltage increases current.

00:05:16.047 --> 00:05:22.157
A transformer cannot increase both output voltage and output current at unchanged input power.

00:05:24.833 --> 00:05:29.229
Rearrange the ideal equation to find a missing voltage or current.

00:05:29.379 --> 00:05:36.437
For example, secondary current equals primary voltage times primary current divided by secondary voltage.

00:05:36.587 --> 00:05:40.686
Check whether the question explicitly assumes an ideal transformer.

00:05:43.367 --> 00:05:50.203
If a real transformer has known efficiency, useful output power equals efficiency fraction times input power.

00:05:50.353 --> 00:05:53.901
Account for losses rather than claiming exact equality.

00:05:56.567 --> 00:06:04.021
The National Grid links generation and electricity transmission; local distribution networks deliver energy to consumers.

00:06:04.171 --> 00:06:07.975
Generation includes power stations and renewable sources.

00:06:10.633 --> 00:06:14.831
Step-up transformers raise voltage before long-distance transmission.

00:06:14.981 --> 00:06:18.252
For the same power, higher voltage means smaller current.

00:06:20.933 --> 00:06:24.673
Cable heating loss is power loss equals I squared times R.

00:06:24.823 --> 00:06:31.531
Reducing current greatly reduces heating losses for the same cable resistance, improving transmission efficiency.

00:06:31.681 --> 00:06:35.357
Halving current reduces I squared times R loss to a quarter.

00:06:40.033 --> 00:06:45.397
Step-down transformers reduce voltage for distribution and again near domestic users.

00:06:45.547 --> 00:06:54.559
UK domestic supply is approximately 230 volts A C; high transmission voltages would be unsuitable for direct household use.

00:06:54.709 --> 00:07:00.195
Illustrates the purpose of voltage changes rather than a universal list of grid voltages.

00:07:04.867 --> 00:07:10.477
Some transmission lines operate at hundreds of kilovolts, for example 400 kilovolts.

00:07:10.627 --> 00:07:17.484
Intermediate and generator voltages vary; the source's numbers are examples rather than one compulsory sequence.

00:07:20.167 --> 00:07:25.158
High-voltage equipment requires insulation, separation and controlled access.

00:07:25.308 --> 00:07:29.525
Lower domestic voltage still presents a serious electrical hazard.

00:07:32.200 --> 00:07:35.574
The grid transfers energy; it does not create it.

00:07:35.724 --> 00:07:41.930
Demand, generation and network operation must be managed, with some energy inevitably dissipated.

00:07:44.600 --> 00:07:50.807
(Higher tier) Moving a conductor relative to a magnetic field can produce (induce) a potential difference.

00:07:50.957 --> 00:07:53.539
Current flows if the circuit is complete.

00:07:53.689 --> 00:08:00.097
A stationary conductor in an unchanging magnetic field does not produce a continuing induced output.

00:08:02.767 --> 00:08:09.345
(Higher tier) An alternator rotates a coil in a magnetic field and uses slip rings to maintain connections.

00:08:09.495 --> 00:08:16.694
As the coil moves through successive half-turns, the induced output changes direction, producing alternating current.

00:08:19.367 --> 00:08:26.587
(Higher tier) A simple D C dynamo uses a split-ring commutator to reverse the coil’s connections every half-turn.

00:08:26.737 --> 00:08:30.807
This keeps the current in the external circuit flowing in one direction.

00:08:30.957 --> 00:08:36.065
Its size can still rise and fall (pulsate), rather than staying perfectly constant.

00:08:38.733 --> 00:08:49.665
(Higher tier) In a moving-coil microphone, sound pressure variations move a diaphragm and attached coil in a magnetic field, inducing a varying voltage that represents the sound.

00:08:49.815 --> 00:08:55.509
A loudspeaker reverses the conversion, using current variations to produce motion and sound.

00:09:00.167 --> 00:09:10.267
(Higher tier) A loudspeaker works by the reverse energy transfer: a varying current in a coil produces a varying force in a magnetic field, moving the cone to create sound.

00:09:10.417 --> 00:09:13.520
Headphones use the same principle on a smaller scale.

00:09:16.200 --> 00:09:23.953
(Higher tier) Generators transfer kinetic energy to electrical energy; microphones transfer sound into electrical signals.

00:09:24.103 --> 00:09:30.032
Energy is conserved and friction, electrical resistance and other losses reduce useful output.

00:09:32.700 --> 00:09:35.132
(Higher tier) For an ideal transformer,

00:09:35.282 --> 00:09:48.389
primary voltage divided by secondary voltage equals primary turns divided by secondary turns: primary voltage divided by secondary voltage equals primary turns divided by secondary turns.

00:09:48.539 --> 00:09:53.827
Use alternating input; the changing core field induces the secondary voltage.

00:09:56.500 --> 00:10:05.491
(Higher tier) A step-up transformer has more secondary turns and a higher secondary voltage; a step-down has fewer secondary turns and lower voltage.

00:10:05.641 --> 00:10:09.461
Turns ratio sets the voltage ratio, not the power gain.

00:10:12.133 --> 00:10:20.153
(Higher tier) With ideal power balance, primary voltage times primary current equals secondary voltage times secondary current.

00:10:20.303 --> 00:10:26.713
Raising voltage lowers current for the same transferred power; a transformer does not create extra energy.

00:10:29.367 --> 00:10:34.189
(Higher tier) Power dissipated in a transmission cable is I squared times R.

00:10:34.339 --> 00:10:42.263
For fixed transmitted power and cable resistance, doubling transmission voltage halves current and reduces cable loss to one quarter.

00:10:42.413 --> 00:10:46.890
These relative values assume unchanged transmitted power and resistance.

00:10:51.567 --> 00:10:59.043
(Higher tier) The National Grid uses step-up transformers before long-distance transmission and step-down transformers for consumers.

00:10:59.193 --> 00:11:06.145
High-voltage transmission reduces current-related heating, but requires suitable insulation and safety systems.

00:11:08.800 --> 00:11:14.005
(Higher tier) Real transformers have energy losses, so output power is less than input.

00:11:14.155 --> 00:11:20.585
Use ideal assumptions only when stated, and distinguish useful output power from the heat lost in cables.

00:11:23.267 --> 00:11:25.922
That completes Electromagnetic induction.

00:11:26.072 --> 00:11:29.417
Revisit the notes and test yourself on the revision website.